IH5610 - CAT3000 Active Repeater
Features

• Repeats both the signals from MicroModules as well as regular Marmitek X-10 transmitters.
• Pre installed in IP54 plastic cabinet: designed to install in the main distribution box.
• Status LED’s on cover.
• Can also be used as signal repeater in a one phase installation.
• Calculates signals on 2nd and 3rd phase from the 1 phase compatible signals of MicroModules.
• Repeats the 3 phase compatible signals of regular Marmitek X-10 transmitters.
• Two way.
• Fuse protected.

LED Display
  • POWER POWER CAT3000 is active
  • GEREED READY Ready for receiving data
  • ONTVANGEN RECEIVE Receiving data
  • VERZENDEN TRANSMIT Transmitting data
  • FOUT ERROR Error in data
Use & Applications

• Use Marmitek MicroModules in a 3 phase installation.
• Signal amplification of X-10 signals on all 3 phases.

Technical information

Installation

Wiring:

Brown L1 Phase 1 + Power (should always be connected to 230V)
Black L2 Phase 2
Black L3 Phase 3
Blue N Neutral
Yellow/Green Earth Earth Connection (not connected inside the repeater)


The CAT3000 should be installed behind a fuse (e.g. 16A). Normally, the best location to hook up the CAT3000 is behind a 3 phase master switch of a 400V power group (e.g. cooking or heating group). When earth leakage switches are installed, the CAT3000 should be installed before the earth leakage switches to prevent the unwanted trigger of the earth leak switches. When you use a 3 phase earth leakage switch with one neutral connection, you will be able to connect the CAT3000 behind it.
Note: Installation position may vary upon local regulations

Technical specifications

  • Supply voltage : 240 VAC (+/- 10%)
  • Frequency : 50 Hz
  • Fuses (non field replacable) :
    Phase A: 5x15mm, 750mA, 350V, time lag
    Phase B: 5x15mm, 750mA, 350V, time lag
    Phase C: 5x15mm, 750mA, 350V, time lag
  • Signal input : 25 mV minimum
  • Signal output : 5Vpp @ 5 Ohms
  • Connections : 1m, VMVK 2,5mm2 ,flying lead
  • Cabinet : Plastic with transparant cover, IP54
  • Dimensions Cabinet : 170 x 135 x 80 mm (LxWxH)
  • Weight : 1250 grams

ENVIRONMENTAL PARAMETERS:
Operation Temparature range 0° to 49° C
Storage Temperature range -20° to 85°C
Operation Humidity range 10 to 95% non-condensing
CE

Download data sheet